INPUT MODULE

Home / Products / Fire Detection System / INPUT MODULE

INPUT MODULE

Description

<br><div style="max-height: 350px;"><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><span style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif; font-weight: bolder;">Addressable Monitor Module </span></span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">The TR-MONITOR is an addressable monitor module for use with the Triga Series fire alarm control panels (FACPs). The TR-MONITOR acts as an interface to contact devices, such as waterflow switches and pull stations.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">The TR-MONITOR supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">INSTALLATION</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">The TR-MONITORR mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box (TR-SMB500) is available from Triga.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">COMPATIBILITY</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">The TR-MONITOR is compatible with the following Triga Series FACPs:<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-2100R / ITR-2100B<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-2100ECSR / TR-2100ECSB<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-R2100R / TR-R2100B</span></p></div><br><div style="max-height: 350px;"><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">INSTALLATION</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">The TR-MONITORR mounts directly into a 4” square electrical box. The box must have a minimum depth of 2-1/8”. A surface mount electrical box (TR-SMB500) is available from Triga.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">COMPATIBILITY</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">The TR-MONITOR is compatible with the following Triga Series FACPs:<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-2100R / ITR-2100B<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-2100ECSR / TR-2100ECSB<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">• TR-R2100R / TR-R2100B</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">PHYSICAL</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">4.5″ H x 4″ W x 1.25 D ( 11.4 x 10.2 x 3cm)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Shipping Weight: 6.3oz (196g)</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ELECTRICAL RATINGS</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Voltage: 15 – 32 VDC<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Current Draw (LED on): 5.0mA max<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Operating Current (LED flashing): 375μA<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Standby Current: 400 μA max @ 24 VDC (one communication every 5 sec with 47K EOL); 550 μA max @ 24 VDC (one communication every 5 sec with EOL &lt;1K)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">5.5 mA (with LED latched on)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">LED Current: 5.5 mA (with LED latched on)<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">End-of-Line Resistance: 47K W<br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">Initiating Device Circuit Wiring Resistance: 1,500Ω max SLC Loop Resistance: 40 W max.</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ORDERING INFORMATION</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-MONITOR: Monitoring Module</span></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"></p><p style="padding: 0px; margin-right: 0px; margin-left: 0px; font-family: Manrope, sans-serif; color: rgb(33, 37, 41); font-size: 16px;"><span style="padding: 0px; margin: 0px; font-weight: bolder;"><span style="padding: 0px; margin: 0px; font-family: Tahoma, ">ACCESSORIES</span></span><span style="padding: 0px; margin: 0px; font-family: Tahoma, "><br style="padding: 0px; margin: 0px; font-family: Manrope, sans-serif;">TR-SMB500: 4” Square surface mount electrical box</span></p></div><br>

Chat with us on WhatsApp!
Online

Hello, how can we help you?